[ Identification | Description | Input parameters | Links ]
Test_Mono InstrumentVery simple setup to compare intensities diffracted by Monochromators. It shows that implementations are equivalent. The inpout parameter Mono chooses which model to use: 0: Obsolete Perfect_crystal 1: Bragg_crystal - validated component 2: Bragg_crystal_bent - bent version of the above 3: Bragg_crystal_BC - variant of the above based on Mendenhall et. al., J. Appl. Cryst 2019 4: Bragg_crystal_bent_BC - variant of the above based on Mendenhall et. al., J. Appl. Cryst 2019 5: Bragg_crystal_simple - a simple mono with a static (flat) Darwin width.
| Name | Unit | Description | Default | 
| Mono | Which monochromator model to use. | 1 | |
| lambda | AA | Source wavelength. | 1.0 | 
| L1 | m | Distance from source to monochromator. | 10.0 | 
| OMM | deg | Rotation angle of monochromator, i.e. angle of incidence. | 14.2208 | 
| TTM | deg | Scattering angle at which to put the detector. | 28.4416 | 
| BEND | m | Curvature radius of the monochromator crystal lattice. Only relevant for Mono==2. | 1 | 
| monsiz | m | Size (h and w) of PSD measuring diffracted beam. | 5e-5 | 
Test_Mono.instr.
  